Vacuum oil filter maintenance
Maintenance of elliptic gear flowmeter for vacuum oil filter. When problems occur, many users first complain about the quality of their products, but in fact, 85% of equipment failures are caused by improper or no maintenance methods. Due to the use of equipment, environmental impacts and changes in some materials over time, equipment must be inspected and maintained regularly.
Let me give you a brief explanation of what the maintenance requirements of the elliptical gear flowmeter are. If the elliptic gear flowmeter is not properly maintained, it will directly affect its accuracy and other performance. In severe cases, the entire device can break down. In the selected environment, oval gear flowmeter, as long as to avoid moisture and water easy to choose dry ventilation, as far as possible to avoid sunlight and rain. In some cases, the device should avoid strong vibration as much as possible. The elliptical gear flowmeter should not be placed on the power supply. After that, it is important that if there is a problem with the equipment, do not move it by yourself and get a professional to fix it. The same elliptic gear meter is used for maintenance, it is the same type of elliptic gear meter.
During the operation of the vacuum oil filter, the polluted oil enters the heater through the inlet under the vacuum suction of the external atmospheric pressure. The heated oil enters the primary filter, and the large particle impurities are filtered out. Then the oil enters the water separator and the vacuum separator and flows through the special divergence device. The divergence device creates a large surface area per unit volume of oil, exposing the contaminated oil to an atmosphere of very low relative humidity, thus removing water, air and gases from the oil. The mixture of evaporated water vapor and gas condenses into liquid through the water tank and cooler. The remaining gas is pumped out by vacuum ch. The oil to remove water is pumped into a fine filter to remove fine particles and impurities, which is to purify the oil. A purification process is completed. According to the amount of water content, several cycles are required to completely remove water.