Transformer Vacuum Drying Oven is applied for drying of oil immersed transformers, transformers, capacitors and other products body,comparing the traditional hot air circulation drying, ordinary vacuum drying and low-frequency drying Equipment, the processing time can be shorten about 1/3, energy consumption can be decreased by 30% -50% and after treatment, the minimum water content of insulating materials can be 5ppm. Comparing the investment with the kerosene vapor phase drying oven,it is 25% -45% of that kind.It is with reliable and energy saving process. Transformation of vacuum drying oven is currently used for voltage 220kv and 110kv ,below the power transformer 500kv ,below transformer and other paper-insulated power. Transformer vacuum drying oven is the best choice for drying equipment.
Working principle: By vacuuming, the saturated vapor pressure of water in the environment where the coil insulation material is located is increased to make it easier to evaporate from the insulation paper. During this period, it is continuously heated to raise the temperature to ensure water gasification energy, let the water easier to discharge.
Specification :Rectangular Design:
Model
Dimension
L*W*H mm
Ultimate vacuum
Leakage rate
Operating temp.
Temp. accuracy
Control mode
VFT-4025
4000×2500×2500
≤50Pa (unload)
≤500Pa.L/S
115±5℃
±5℃
Auto control by HMI
VFT-4030
4000×3000×3000
≤50Pa (unload)
≤500Pa.L/S
115±5℃
±5℃
Auto control by HMI
VFT-5030
5000×3000×3000
≤10Pa (unload)
≤500Pa.L/S
115±5℃
±5℃
Auto control by HMI
VFT-5035
5000×3000×3500
≤10Pa (unload)
≤500Pa.L/S
115±5℃
±5℃
Auto control by HMI
VFT-6040
6000×4000×4000
≤10Pa (unload)
≤500Pa.L/S
115±5℃
±5℃
Auto control by HMI
VFT-7545
7500×4000×4500
≤10Pa (unload)
≤500Pa.L/S
115±5℃
±5℃
Auto control by HMI
VFT-8545
8500×4500×4500
≤10Pa (unload)
≤500Pa.L/S
115±5℃
±5℃
Auto control by HMI
VFT-9050
9000×4500×5000
≤10Pa (unload)
≤500Pa.L/S
115±5℃
±5℃
Auto control by HMI
(The article comes from the Internet. If reprinting is not allowed, please contact our company to delete it.)
CONTACT US
Please send us your inquiry about the customization of other furnace types or related questions about vacuum furnace. We will reply you immediately. Thank you.
Transformer Vacuum Drying Oven
Transformer Vacuum Drying Oven is applied for drying of oil immersed transformers, transformers, capacitors and other products body,comparing the traditional hot air circulation drying, ordinary vacuum drying and low-frequency drying Equipment, the processing time can be shorten about 1/3, energy consumption can be decreased by 30% -50% and after treatment, the minimum water content of insulating materials can be 5ppm. Comparing the investment with the kerosene vapor phase drying oven,it is 25% -45% of that kind.It is with reliable and energy saving process. Transformation of vacuum drying oven is currently used for voltage 220kv and 110kv ,below the power transformer 500kv ,below transformer and other paper-insulated power. Transformer vacuum drying oven is the best choice for drying equipment.
Working principle: By vacuuming, the saturated vapor pressure of water in the environment where the coil insulation material is located is increased to make it easier to evaporate from the insulation paper. During this period, it is continuously heated to raise the temperature to ensure water gasification energy, let the water easier to discharge.
Specification :Rectangular Design:
L*W*H mm